For the first time user, please collect the application information and send it to us for correct configuration. The questionaire sheet (pdf version) (Word Version) will help you to think through.
For 19" rack mounted product, please check BM systems.
Refer to application page, most cases will need:
1) TM module
2) RM module (Optional for IR data acquisition, one module for one string)
3) Control Panel (Optional)
4) Sensors and accessories
BatteryDAQ Modules
Order Number |
Description |
TM-12 |
DAQ module, 12 channels at 2-wire mode, 24 channels at 1-wire mode |
TM-24 |
DAQ module, 24 channels at 2-wire mode, 48 channels at 1-wire mode |
TM-30 |
DAQ module, 30 channels at 2-wire mode, 60 channels at 1-wire mode |
| TM-40 |
DAQ module, 40 channels at 1-wire mode for 600V high voltage UPS |
IR Modules Order Number
String Voltage |
L (<200Ah) |
M (200 to 800Ah) |
H (800 to 3000Ah) |
48V |
RM-48-L |
RM-48-M |
RM-48-H |
110V |
RM-110-L |
RM-110-M |
RM-110-H |
220V |
RM-220-L |
RM-220-M |
N/A |
400V |
RM-400-L |
RM-400-M |
N/A |
| 600V |
RM-600-L |
N/A |
|
Control Panel
Order Number |
Description |
CM65-S-EXCEL |
Excel sheet Panel, Microsoft Office software not included |
CM65-S-WIN |
Software panel, installation version. Run in PC windows 2000, XP |
CM65-DEV-WIN |
Drive and example source code for easy integration development |
CM65-DEV-LABVIEW |
Drive and example for LabVIEW |
CM65-GT-01 |
Panasonic GT-01 with preloaded software. |
Sensors and Accessories
Order Number |
Description |
LA-55-W-C |
LEM 50A sensor with 2m wire and calibration |
LA-100-W-C |
LEM 100A with 2m wire and calibration |
HTB-400-W-C |
LEM 400A sensor with 2m wire and calibration |
HOP-200-W-C |
LEM 200A split core sensor with 2m wire and calibration |
HOP-500-W-C |
LEM 500A split core sensor with 2m wire and calibration |
DR-60-24 |
DIN rail 24V AC/DC Power |
CN-24 |
Phoenix Contact COMBICON Plugs for TM-24 |
CN-30 |
Phoenix Contact COMBICON Plugs for TM-30 |
WL-1 |
O-ring fused lead |
Configuration Examples
Example 1: Telecom Central Office, 48V DC, 2 strings of 1500Ah 2V VRLA batteries, 24 cells in each string.
Product |
Quantity |
TM65-24 |
2 |
RM-48-H |
2 |
CM65-GT-01 |
2 |
HOP-200-W-C |
2 |
CN-24 |
2 |
WL-1 |
100 |
CM65-S-WIN |
1 |
|
 |
Example 2: Electric Utility DC Power, 110V, 2 strings of 650Ah 2V VRLA batteries, 58 cells in each string.
Product |
Quantity |
TM65-30 |
4 |
RM-110-M |
2 |
CM65-GT-01 |
1 |
LA-100-W-C |
1 |
CN-30 |
4 |
WL-1 |
120 |
CM65-S-WIN |
1 |
Example 3: UPS Power, 1 string of 100Ah 12V VRLA batteries, 32 or 33 batteries in total.
Product |
Quantity |
TM-40 |
1 |
RM-400-M |
1 |
CM65-GT-01 |
1 |
HASS-100-W-C |
1 |
CN-40 |
1 |
WL-1 |
40 |
CM65-S-WIN |
1 |
|